KOMEG Technology Ind Co., Limited
|
Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
5.1 Description and Application
The purpose of a temperature test is to verify the resistance of a specimen to the environmental influence of temperature. The tests are aimed at the suitability for use and storage at low and high temperatures. In research and development laboratories, the functionality and usability of a product are determined at a very early stage.
5.2 Features
(1) Accurate temperature heating and cooling control
Features temperature heating 3/min and cooling performance at 1/min with no load for our standard model, and can handle temperature cycle tests at 3/min cooling down and heating up rate respectively with load for customized model.
(2) Highly temperature uniformity distribution
KOMEG offers Highest 0.5 temperature uniformity distribution,this allows minimizes variations in test results over multiple specimens.
(3) Wide Selection control range for temperature and humidity
Features a wider cont rol range of temperature and humidity, including stable control at 95/98RH.
(4) Network solution available
Standard communication support is available with RS-485 or RS-232C interface.
An Ethernet (LAN) port is also available as an option, for simple connection of a computer, tablet computer, or other terminal. Monitoring of chamber’s running conditions, modification of test conditions, starting or stopping operation, and other interaction with the chamber can be performed via a Web browser.
(5) Less temperature and humidity stabilization time
Temperature and humidity stabilization time have been greatly saved by minimizing hunting as the chamber approaches set-point. (under testing operation from RT to 85/85 rh).
(6) Color LCD touch-screen Man-Machine interactive system
Operation and settings simplified by the set of a touch-screen LCD display (instructions displayed on-screen). At-aglance confirmation of test patterns, test area temperatures, temperature cycles, upstream / downstream control, and trend graphs display.
(7) Specimen temperature control function provides accurate testing
Uses a temperature control sensor (×1) to monitor and control the temperature of the specimen.
(8) Alarm buzzers and displays
When an alarm triggers, alarm information, date and time of occurrence are displayed on screen. A second screen displays the cause and cor rective actions.
5.3 Specification
(1) KMH-R series
Model |
KMH-R series |
|||||
150R |
225R |
408R |
800R |
1000R |
||
Temp. range |
-20°C 150°C |
|||||
Interior size |
W(mm) |
600 |
700 |
700 |
1000 |
1000 |
H(mm) |
600 |
700 |
750 |
1000 |
1000 |
|
D(mm) |
460 |
480 |
800 |
800 |
1000 |
|
Exterior size |
W(mm) |
880 |
980 |
980 |
1280 |
1280 |
H(mm) |
1730 |
1890 |
1940 |
2160 |
2160 |
|
D(mm) |
1400 |
1460 |
1740 |
1750 |
1950 |
|
Power(KW) |
5.8 |
6 |
7.5 |
12.8 |
12.8 |
|
Weight(KG) |
240 |
280 |
400 |
500 |
580 |
|
Humidity uniformity |
±3.0R.H |
±5.0R.H |
||||
Heat up time |
-20°C +100°C ,within 35 min |
|||||
Pull down time |
+20°C -20°C , within 45 min |
|||||
Humidity Range |
2098R.H |
|||||
Temp. constancy |
±0.5ºC |
|||||
Humidity constancy |
±2.5R.H |
|||||
Temp. uniformity |
±2.0ºC |
|||||
Safety device (standard) |
NFB, over pressure,over heat and over current protection for compressor, Over temp. protect, over load protect of blower, dry heat protection |
|||||
Interior material |
Stainless Steel Plate(SUS 304) |
|||||
Exterior material |
Baked Painting Steel Or Stainless steel(SUS304) |
|||||
Insulation material |
Rigid polyurethane Foam and Glass Fiber Wool |
|||||
Ambient Temp. |
+5°C +35°C |
|||||
Wiring method |
AC 380±10 50Hz ,3 phase 4 wires +Ground Wires |
|||||
Controller |
LCD Touch Screen, Chinese or English display selectable |
|||||
Operation model :Program or fix point running |
||||||
Memory capacity :120programs,1200steps, |
||||||
All repeat 999 cycles, part repeat 99 cycles |
(2)KMH-L series
Model |
KMH-L series |
|||||
150 L |
225 L |
408 L |
800 L |
1000 L |