Place of Origin: | Zhejiang, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Easy Assembling 27.1 Cubic Walk-In Temperature and Humidity Chamber
1. Temperature Ranges
Various ranges can be provided, including fast change rates with your product load. Ranges from -60°C (-140°F) to +85°C are available.
2. Humidity
2.1 Humidity Range:
Standard ranges available are: 20% to 95% ±5% RH. 10% to 98% ±2% RH.
Different ranges available including special dehumidity ranges to 5% RH.
Two Humidity systems are standard:
1) Fine Mist System is recommended when doing continuous testing with high live loads.
2) Steam Generator System is recommended for rooms being used for low and high humidity testing within the System range of +5°C ( +40°F ) to +55°C ( +130°F) .
The conditioned Fine Mist System uses your local water supply. Steam is created within a plenum outside the room area by spraying a fine mist over a stainless steel sheath-type heater. The circulation system carries this steam throughout the walk-in room.
The Steam Generator System uses an external self-contained steam generator with all necessary safety and water level controls to provide humidities to saturation point within the walk-in room.
3. Parameters
Inspect standard: JJF-1101,GB/T 10592,GB/T 10586
Testing standards: YD/T 2061,HB 7122.3,6783.7,GJB 5382.7,GJB 150,GB/T 2423,5170.2,5170.5,5179.2, ASTM E512,NF EN 60068-2-38,CNS 12565,12566,KS C0227,KS C022
Specifications
Specification of Walk-In Chambers | ||
Model |
KMHW-13 |
|
Volume(m³) |
27.1CBM |
|
Interior Dimensions |
W3000 X H2100 X D4300mm |
|
Exterior Dimensions |
W5050 X H2350 X D2250mm |
|
Safety Devices(standard) |
No fuse breaker, over pressure,over heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection |
|
Standard accessories |
Sight window*1,cable port ( portΦ50mm )*1,chamber lamp*1, status indicator |
|
Control System |
Balanced Temperature & Humidity Control System |
|
Refrigeration system |
Water Cooled |
|
Semi-hermetic compressor, single stage or cascade refrigeration system, |
||
CFC free refrigerant ( HFC-507 and HFC-23) |
||
Controller |
Panel |
7-inch LCD Touch panel, Chinese or English display selectable |
Operation model |
Program or fix point running |
|
Memory capacity |
120 programs, 1200steps, all repeat 999 cycles, part repeat 99 cycles |
|
Accuracy |
Temp.: 0.1% of F.S ±1 digit Humidity: 0.1% of F.S±